Description
SED 21: Vulnerability and Retrofitting Techniques for Non-engineered Unreinforced Masonry (URM) Buildings in Seismic Prone Countries
Editor (and Author): Andreas Lampropoulos; Authors: Eftychia Apostolidi, Stephanos Dritsos, Christos Giarlelis, Jose Jara, Anna Karatzetzou, and Konstantinos Morfidis
Unreinforced masonry structures (URM) are prevalent in under-developed and developing countries. The majority of these URM structures are not engineered, they simply follow local construction techniques and usually do not comply to any seismic standards.
After a thorough description of the methods of construction and the materials used for URM buildings all over the world, the most common seismic damage and failures types for each system are presented and explained through figures and actual case study pictures. Then the book focuses on the low-cost repair, strengthening and retrofitting tailored for non-engineered (URM) buildings in seismic-prone regions. Emphasizing on local and global stability, it encompasses a diverse spectrum of strengthening approaches. Each technique is meticulously described, providing insights into its range of applications, the basic scientific concept and key considerations for the design and the application process. Through meticulous planning and execution, these techniques enhance seismic resilience while considering factors such as building condition, seismic hazard, and cultural significance.
This state-of-the-art document encompasses the knowledge assimilated from the effect of past seismic events on different types of URMs and aims to empower communities in safeguarding lives and heritage against seismic hazards providing solutions both cost-effective and comprehensive. It focuses on low-cost seismic repair, strengthening and retrofitting techniques, considering the main URM structural typologies and respective seismic failures in under-developed and developing countries and could serve as a useful tool for practical engineers and designers.